Profibus DP Communication Board - EXB014A01
Allows connection to Profibus DP communications bus. Uses plug in terminals for connection.
Modbus Plus Communication Board - EXB015A01
Allows connection to Modbus Plus communications bus. Uses plug in terminals for connection.
Group 1 and Group 2 Ordering/Mounting Information
• NOTE: Expansion boards plug into the main control board inside the control. When using one expansion board, either
a Group 1 or Group 2 board will connect to the main control board. When two expansions boards are used, one must
be from Group 1 and one from Group 2. The Group 1 board will connect to the main control board and the Group 2
board will connect to a stacking connector on the Group 1 board.
Accessory Boards
Isolated Input/2 Relay Output Accessory Board - ACB003A01
Contains 9 isolated inputs for 90-130 VAC. Also has 2 Relay outputs, Form C: N.O. and N.C. Accessory board mounts
in expansion board slot but uses wiring harness to connect to motor control card.
Catalog Cable Extension Approx.
Number Length Shpg. Wgt.
CBLH015KP 5 Feet (1.5 Meter) 2
CBLH030KP 10 Feet (3.0 Meter) 4
CBLH046KP 15 Feet (4.6 Meter) 6
CBLH061KP 20 Feet (6.1 Meter) 8
CBLH091KP 30 Feet (9.1 Meter) 12
CBLH152KP 50 Feet (15.2 Meter) 18
CBLH229KP 75 Feet (22.9 Meter) 26
CBLH305KP 100 Feet (30.5 Meter) 30
Keypad Extension Cable
For the convenience of our customers,
we offer a connected plug/cable
assembly. This
assembly provides
the connectors from
the keypad to the
control for remote
keypad operation.
Maximum Braking Torque in % of Motor Rating Cont. Catalog
HP 20 25 30 40 50 60 75 100 150V 150 200 250 Watts Number
200 90% 75% 60% 45% 36% - - - - - - - 600 RBA2-610
to 150% 125% 100% 75% 62% - - - - - - - 1800 RBA2-1806
240 150% 150% 150% 115% 92% - - - - - - - 4000 RBA2-4004
380 150% 150% 120% 90% 72% 60% 48% 36% 28% - - - 600 RBA4-620
to 150% 150% 120% 90% 72% 60% 48% 36% 28% - - - 1800 RBA4-1820
480 150% 150% 150% 150% 150% 120% 96% 72% 56% 48% 36% 29% 4000 RBA4-4010
550 150% 150% 120% 90% 72% 60% 48% 36% 28% - - - 600 RBA5-624
To 150% 150% 120% 90% 72% 60% 48% 36% 28% - - - 1800 RBA5-1824
600 150% 150% 150% 150% 150% 120% 96% 72% 56% - - - 4000 RBA5-4014
Dynamic Braking Assemblies (RBA)
Dynamic Braking Assemblies include braking transistor and braking resistors completely assembled and mounted into a NEMA 1
enclosure. Select braking assembly from table with adequate maximum braking torque(%) and continuous regenerative
power(Watts) capacity to meet load requirements. For use with -EO controls.
Input Voltage