MN1240 Installation 2-3
Shaft Loads The motors can be damaged by excessive shaft loads. This may shorten
the motor’s service life. The motor warranty is also voided for excessive shaft
load related failures.
The maximum allowable radial force (
F
radial max
) depends on the shaft load. It
is determined by (distance x force) and the output shaft design (plain shaft or
shaft with keyway). When motor shaft has both a radial load and an axial
load, axial load rating = 44% of radial load rating listed. Should questions
arise contact Motion_Support@Baldor.com
Figure 2-2 Radial Load Capacity
Notes:
1) Solid lines are based on L
10
= 20,000 hours.
2) Dashed line is based on 10
4
load peaks @
110% of rated torque.
X"
(Radial Force)